REPORT
INTERTEK, ETL SEMKO

3933 US ROUTE 11 CORTLAND, NEW YORK 13045


Project No. 3083323
Date: November 1, 2005

REPORT NO.
3083323CRT-002

RENDERED TO:
Bentax USA
418 Meadow Street
Fairfield, CT 06824

Report Scope:

Performance testing of Duct Air Cleaners and a Portable Household Cord Connected Room Air Cleaner.
Limitation Statement: The test data and results contained in this report are provided for client information and evaluation. No conclusions are drawn by Intertek.
Authorization: The tests were authorized by signed Intertek Quote No. 18324499 dated September 2, 2005.
Standards Used: Modified ANSI/AHAM AC-1-2002 entitled, "American National Standard Method for Measuring Performance of Portable Household Electric Cord-Connected Room Air Cleaners"
Sample Description: Four units were supplied by the client and received on September 8 and 9, 2005 and appeared to be in good condition. One Bentax 100C air cleaner unit was brought by the client to the laboratory on December 13, 2004
Date of Tests: September 8 and 9, 2005; December 13, 2004



Test Method:
Objective

To evaluate the effectiveness of White-Rogers SST1000, Honeywell F300E Lennox PCO-12C, Ionic Breeze 3.0 and Bentax USA's air purification eqiupment by comparing its reduction of airborne particles to a control's natural decay in a typical indoor environment. The environment has been designed to be similar to a typical consumer application such as homes, offices, etc. The key to our experiment is to eliminate any outside influences not consistent with a typical commercial or residential environment.

Testing Method

Test facility

The tests were conducted in a closed room 10.5 x 12 x 8 ft equipped with an exhaust system to clean the room between tests. The room also had a ceiling fan used primarily for evenly spreading the contaminants injected into the room for the most accurate measurements.

In order to test this specific equipment, a duct system was utilized to supply air to the room in order to model, as close as possible, a real indoor environment. The sypply air was taken from outside the test chamber. The air cleaning equipment was installed in this duct system which was supplied a measured amount of air into the room.

Dissemination of dust particles into the closed room

Roughly One (1) gram of dust particles was introduced into the test room by utilizing an injection system. The contaminant was spread evenly in the closed room by the ceiling fan mounted in teh middle of the room's ceiling. The fan was on as the contaminant was introduced into the room and was turned off after 60 seconds. The particle count was measured using a TSI Aerodynamic Particle Sizer Model 3321.

Temperature and humidity

The temperature was held at a level between 65 degrees F and 75 degrees F, and the humidity was held at a level between 35% and 45%. The temperature was measured by a Vaisala Temperature/Humidity Sensor Model HMW30YB.

Data logging

The particle data were recorded continuously by an automated computer data acquisition system directly connected to the TSI Particle Sizer. Data was logged every minute during the test period using a proprietary software program, the temperature and humidity was averaged over the period.

Testing

The steps of the actual testing procedure were as follows:

Commercial building

  1. The room was cleaned by the heavy duty exhaust system that re-circulates the air until the contamination level of airborne particles in the room is below 0.03 part/cc.
  2. The heavy duty exhaust system was turned off.
  3. The air contaminants, dust particles were introduced by an injection system and then spread evenly in the room for 60 seconds using the ceiling mounted fan.
  4. Measurements of the decay of the particles in the air were taken and recorded by the data-logger.

These measurements were conducted first on the controlled natural decay of the particles. After that was completed, steps (a) through (d) as described above were repeated with specific equipment turned on.

Equipment Used Model Number Intertek Control # Cal. Due Date
Laser Aerosol Spectrometer HSLAS 0.065 N829 12/05
Aerodynamic Particle Sizer 3321 A-261 01/05
Fluidized Bed Aerosol Generator 340000 -- --
Sola Voltage regulator (120 Vac) MCR V245 06/05
Temperature/Humidity Sensor HMW30YB T680 11/05
Power Transducer AGH-002B E399 04/05

Results

Results of Performance Tests:

Model/Configuration Test Particulate Natural Decay Rate CADR CADR STDEV.
White-Rogers SST1000-Comfort Plus
Serial # S0516464671
64.8 CFM - 82.6 Average Duct Velocity
Dust 0.01017 27.2 0.6
Honeywell F300E 100 Enviro-Care Elite
Serial # 208418J
63.7 CFM - 81.1 Average Duct Velocity
Dust 0.01284 35.8 0.5
Lennox PCO - 12C - Healthy Climate
Serial # S2105H48156
64.2 CFM - 81.78 Average Duct Velocity
Dust 0.01136 47.4 0.6
Ionic Breeze 3.0
Serial # 3252147 68.99 CFM - 87.89
Average Duct Velocity
Air flow loop running during natural
Dust 0.01258 4.8 0.3
Bentax 100C Dust 0.00424 125.0 2.5

 

Summary

Testing of the above units was designed to simulate real world use. A test chamber duplicating typical household conditions was modified to introduce outside air processed by the units as might be seen in a standard installation.

Report Reviewed By: Terence J. O'Beirne, Senior Project Engineer, Appliance Group
Tested By: Dominick A. Pennello Jr., Appliance Group